Filter Results By:
Products
Applications
Manufacturers
Current Transformers
transfers accurately proportional levels of current to multiple circuits.
-
product
1 A DIGITAL MILIOHMMETER
MO-2Ke
The MO-2Ke digital low resistance ohmmeter is a portable, microprocessor-controlled instrument used to accurately measure resistances of contacts, switches, transformer and motor windings, etc., using test currents from 1 mA up to 1 A.It uses the Kelvin-type (4-terminals) measurement principle, thus eliminating errors caused by lead and contact resistances.Resistance readings are shown in the alphanumeric display with up to a 4 digit-resolution. It allows to measure resistances of up to 2 kO, with resolution of 0.01 mO.Measurements accuracy is guaranteed by the state-of-the-art system for signal-amplification, offset-free and with long-term stability.
-
product
Three-Phase Transformer Winding Resistance Meters
TWA Advanced Series
TWA Advanced series is the latest DV Power solution for three-phase transformer winding resistance measurement and tap changer analysis. They are capable of testing six transformer windings with a single cable connection, as well as three-phase automatic transformer demagnetization. It has the option of the automated test mode, where the instrument operates the tap changer without operator input (minimizing the risk of human error) and records winding resistance results based on pre-selected stabilization criteria.The unique DVtest method of tap changer analysis enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, together with the measurement of tap changer motor current which detects motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or simultaneously on three phases. It can also be performed together with the winding resistance test in all tap positions.A unique advantage of TWA Advanced instruments is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer connected in a YN configuration. This can significantly speed up the testing– for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.TWA500 is equipped with a large 10.1” graphical touch-screen display, while TWA400 has a 7” graphical touch-screen display. Besides making the interface much more user-friendly compared to older winding ohmmeters, it also enables certain test options that were previously available only with DV-Win software. The most important among them are DVtest, tap changer motor current measurement, “Heat Run” test, test templates, and automatic test mode.
-
product
Three Phase Power Analyzer
Model TFT780
Three Phase Power Analyzer PA700TFT is multi-range power Analyzer with basic 0.05% R+R accuracy. 8 range of voltage, 8 range of current and total 64 range of power and power factor gives more accurate result at low power factor. It has waveform mode to check the waveform of voltage and current. As well it has B/H curve mode where user can check live b/h curve of the transformer under test. The gap less four-quadrant power measurement technique gives better accuracy at distorted waveforms or AC drive (VFD) operated power supply.
-
product
Enhanced SCR Power Controller
Thyro-PX DC
The Thyro-PX DC series shapes the future of the growing hydrogen and DC heating markets. The SCR power controller series takes advantage of the existing Thyro-PX controller card architecture and is available as three-phase units, supports up to 1800 amps DC Current, and offers superior interface options. Integrate operating modes and parameters seamlessly with the 2.8-inch, LED Thyro-Touch display and enable efficient system parameters, loading, and storage via an onboard SD-card. The Thyro-PX power controller is ideally suited for your transformer and resistive loads for glass, metal, and ceramic manufacturing. It is optimal for heating elements in electric furnaces.
-
product
HIGH VOLTAGE SCR CONTROLLED POWER SUPPLY
xPS Series
High Voltage SCR Controlled Power Supply, P/N 18278PS Power Rating: 350 KW. Input: 480 VAC, 3 PH, 60 Hz Output: 0 to 5000 VDC, 70 Amps max Ripple: 2 % approximately at maximum rated voltage Configuration: 12 pulse externally SCR controlled rectifier system Protection Devices: Input contactors Overload relay shutoff Input surge suppressor Thermal switches Output current limiting resistor (made with 5 Ohm Kanthal heating element) Emergency power shutoff Cooling: Each 6 pulse rectifier assembly is cooled by three 10” fans Interface: 4/20 ma converter interface for output voltage and output current to SCR controller. Enclosure: The overall dimension of the unit is (78”H x 38”W x 53”D). It is comprised of two separate enclosures each with dimensions of (78” H x 38” W x 26” D) which are integrated together to form a single enclosure. Each half enclosure has one 6 pulse transformer and one 6 pulse high voltage rectifier. Weight: Approx. 5000 lbs. SCR Controller: The 12 pulse SCR controller is supplied by the customer. We were responsible for the 12 pulses Transformer and 12 pulses Rectifier section. Portability: Unit can be lifted up with a fork lift. It can also be moved around with a 5000 lb pallet jack. Transformer: Two 200 KVA transformers are used to step 480 VAC to 3750 VAC each in a 12 pulse configuration Rectifiers: Two 6 pulse rectifier assemblies capable for 5000 VDC and 60 Amps output were used. The high voltage rectifier assemblies are isolated and protected in a fiberglass plenum within the enclosure. Blocking Diode: Each diode of the 6 pulse rectifier consists of 10 diodes in series to offer a blocking voltage of 12000 V (PIV)
-
product
Digital Insulation Testers
The Motwane Manufacturing Company
Motwane is India’s first company to design and develop an intelligent digital insulation tester that conducts insulation resistance tests on high voltage electrical equipment. Products like transformers, generators, motor cables, bushings, LAs, and switchgear, are prone to gradual degradation over time due to the adverse effects of temperature, humidity, and dust. The gathered test data allows clients to verify the current quality of insulation, and take appropriate action.
-
product
Turns Ratio Testers
TRT Standard Series
When it comes to choosing a transformer turns ratio tester, TRT Standard series offers some of the most advanced instruments with LCD display out in the market. Each model measures transformer excitation current and phase shift performs automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. Furthermore, they have a built-in true three-phase power source. Because of that, TRT Standard instruments can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 250 V AC, depending on the chosen model. High test voltage of 250 V AC provides more accurate turns ratio testing compared to other turns ratio testers on the market and extremely low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT Standard series consists of:TRT03 Models (TRT03A, TRT03B, TRT03C) – single-phase voltage up to 100 VTRT3x Models (TRT30A, TRT30B, TRT30C, TRT33A, TRT33B, TRT33C) – single and true three-phase voltage up to 100 VTRT63 Models (TRT63A, TRT63B, TRT63C) – single and true three-phase voltage up to 250 VMore about models differences can be found under the downloads tab, in brochures and comparison sheets.A user can create test templates using the DV Win software and store them in the PC’s memory for later use when in the field.TRT Standard series models have a built-in tap changer control unit. Consequently, it enables remote control of an on-load tap changer (OLTC) directly from the tester. In order to make the most out of this feature, the DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time.
-
product
PC Controlled Bench Top Power Analyzer
PA2100
The PA2100 is a PC controlled bench top power analyzer, allowing several electrical power measurements to be taken simultaneously during testing - from just one set of input connections. The PA2100's power measurement ability is a must in research and development, manufacturing and required for certification and traceability of manufactured goods. In addition to power measurements, apparent power (VA), harmonics, voltage, current, power factor can all be viewed and stored with ease. The PA2100 wattmeter simply connects between the ac supply and the load, various current transformer options allow measurement with any size of current from 10mA to 10000A. Typical watt meter applications include appliance testing; microwave ovens, electric stoves, heating, air conditioning, TVs, monitors, computers, electronic lighting, fans and motor controllers. Powertek wattmeters are equipped with 4mm/banana safety terminals along with optional "breakout" boxes and clamp current probes for fast and safe measurement.
-
product
Variable Frequency Series Resonance Test Device
WABP
Wuhan Sangao Electrical Test Installations Limit Co.
The device mainly AC voltage withstand test design for 10kV, 35kV, 110kV, 220kV, substation and line of all electric main equipment.Reactor with multiple separate design, Not only can meet the requirements of equipment testing conditions high voltage, small current, and can meet the requirements of low voltage AC voltage withstand test, has a wider scope of application.The device is mainly composed of variable frequency control power supply, transformer, reactor, capacitor divider.
-
product
Transformer Testing
The ART-3D series of Automatic Ratio Testers are precision instruments, designed to measure the turn ratios, phase displacements, excitation currents of single phase and three phase power, distribution and instrument transformers in conformity to the IEEE C57.12.90 & IEC 60076. Now featuring an enhanced test lead design, the ART-3D is the perfect instrument for real-life field usage. ART-3D series also has Anti Induction circuit which makes it suitable for system voltages upto 765KV.
-
product
High-Voltage Test Device
PGK 70 HB
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR PGK HB. There are hardly any other longer-lasting, more robust and cost-effective testing devices than the two-piece high-voltage test devices from the PGK HB series. They generate continuous adjustable test voltages with mains frequency or optionally DC with positive or negative polarity. The display instruments for current and voltage, the safety control unit and the regulating transformer for the voltage are integrated in the operating unit.* Testing of medium- and high-voltage cables* DC voltage testing of up to 70 kV output voltage with positive or negative polarity* AC voltage testing - up to 55 kV for switchgear, busbars and insulating elements* Easy-to-maintain 2-piece design
-
product
High-Voltage Test Device
PGK 260 HB
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR PGK HB. There are hardly any other longer-lasting, more robust and cost-effective testing devices than the two-piece high-voltage test devices from the PGK HB series. They generate continuous adjustable test voltages with mains frequency or optionally DC with positive or negative polarity. The display instruments for current and voltage, the safety control unit and the regulating transformer for the voltage are integrated in the operating unit. *Testing of medium- and high-voltage cables * DC voltage testing of up to 260 kV output voltage with positive or negative polarity * AC voltage testing - up to 190 kV for switchgear, busbars and insulating elements * Easy-to-maintain 2-piece design
-
product
High-Voltage Test Device
PGK 150 / 5 HB
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR PGK H. There are hardly any other longer-lasting, more robust and cost-effective testing devices than the two-piece high-voltage test devices from the PGK HB series. They generate continuous adjustable test voltages with mains frequency or optionally DC with positive or negative polarity. The display instruments for current and voltage, the safety control unit and the regulating transformer for the voltage are integrated in the operating unit.* Testing of medium- and high-voltage cables* DC voltage testing of up to 150 kV output voltage with positive or negative polarity* AC voltage testing - up to 110 kV for switchgear, busbars and insulating elements* Easy-to-maintain 2-piece design
-
product
High-Voltage Test Device
PGK 110 HB
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR PGK HB. There are hardly any other longer-lasting, more robust and cost-effective testing devices than the two-piece high-voltage test devices from the PGK HB series. They generate continuous adjustable test voltages with mains frequency or optionally DC with positive or negative polarity. The display instruments for current and voltage, the safety control unit and the regulating transformer for the voltage are integrated in the operating unit.* Testing of medium- and high-voltage cables* DC voltage testing of up to 110 kV output voltage with positive or negative polarity* AC voltage testing - up to 80 kV for switchgear, busbars and insulating elements* Easy-to-maintain 2-piece design
-
product
Single-Phase Transformer Winding Resistance Meters
RMO-TD Series
Using the most advanced switch-mode technology available today, the RMO-TD series is ideal for winding resistance measurements of inductive objects. Transformer resistance meters and tap changer analyzers are perfect for testing:transformer windings (power transformers, distribution, autotransformers),all types of tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.In addition, transformer demagnetization can also be done with all RMO-TD instruments.The RMO-TD series contains 3 models, with maximal test currents from 25 A (RMO25TD) to 60 A (RMO60TD).The three independent voltage sense channels enable testing of three windings in series. This enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.All RMO-TD transformer resistance meters have a built-in tap changer control unit. It enables remote control of on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, DV-Win software is included which can be programmed to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.
-
product
AC Resonant Test System
Yangzhou Power Electric Co., Ltd
Testing of certain apparatus requires much high voltage or current that a straight AC test system is not sufficient. Thus resonant test reactor with a variable core is needed. The main advantage of such test systems is lower input power and larger output power. The resonant test system is designed to compensate capacitance in the testing circuit precisely by tuning inductance of the test system. AC resonant test system is used for factory testing of middle, high and ultra-high voltage cables, capacitors, generators, motors, power transformers and gas-insulated switchgears.
-
product
Megohmmeter Insulation Tester
AMIC-30
The AMIC-30 insulation tester is a small portable meter designed to measure insulation resistance in electrical and telecommunications installations, cables, motors, transformers and other equipment. The test voltage can be programmed in steps from 10 V to 1000 V. The instrument can measure both insulation resistance over a wide range (0,1kΩ...100GΩ), and insulation leakage current, capacitance and other parameters. All test results can be stored in the internal memory and sent to a computer via the included wireless USB receiver. The meters are supplied with rechargeable Ni-Cd batteries.
-
product
Military-Style DC Solid-State Relay for High-Current Pulse Load Applications
Part No. M33-2N
The M33-2N is a military-style DC solid-state relay designed for high-current pulse load applications. It features the latest power FET output technology to minimize ON resistance. This feature provides minimum output voltage drop and allows the M33-2N to switch high pulse currents up to 100 amps at higher temperatures than those allowable with bipolar devices. The M33-2N utilizes transformer isolation to protect against transients, and are through-hole mountedMSL 1 Available options include:M33-2 7Adc, 60Vdc Load; 4.5-5.5Vdc (bias voltage), 80µA (CMOS) Control;
-
product
Real-Time Online Monitoring to Detect and Analyze Potential Partial Discharge (PD) Signals and Insulation Faults using UHF, AE, and HFCT
PDMonitor
Power Monitoring and Diagnostic Technology Ltd.
The PDMonitor, which utilizes Ultra High Frequency (UHF), Acoustic Emission (AE) and High Frequency Current Transformer (HFCT) sensors and is designed to conduct real time online monitoring to detect and analyze potential Partial Discharge (PD) signals and insulation faults before they lead to breakdown or catastrophic failure in power assets. The system provides the developing trend of the PD, when occurring, as alarms in real time, thus helping to predict the insulation degradation status of the asset, prevent sudden accidents, and provide an effective database for Condition-Based Maintenance (CBM) of power assets.
-
product
Load Cell Power Supply
MODEL PSMR
The PSM-R is a self contained AC power bridge excitation supply. This device consists of a low interwinding capacitance AC transformer and a high stability adjustable linear regulator designed specifically for driving transducer bridges. DC excitation is adjustable from 4 to 15 volts output and is capable of supplying 0 to 150 mA in output current. It features remote sensing to eliminate line drop errors and very low noise. It can also be used as a high quality voltage source or reference in many applications. AC input requirements are 105 to 125 VAC at 60 Hz.
-
product
High Voltage System
HV-2
International Electro-Magnetics, Inc.
*Tests Power Transformers for Continuity, Ratio and Phase. Applied and Induced Potential and No-load Losses.*14 Conductor Switching Matrix will test 7 individual windings, 13 taps of one common winding or some combination thereof. (10 Amp current limit)*The System Control is Windows/Visual Basic based. Menu screens allow full selection of test parameters and sequence. Low voltage tests can be performed first, allowing defective parts to be rejected without proceeding to time consuming induced Potential dwell routines. Test data labeling and data acquisition software can be easily added to the system.
-
product
Digital LOOP/PSC/LOAD Tester
2811 LP
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Displays and sound warning if external voltage present.● Displays mains voltage, scroll trough menus.● Checks wiring integrity (LEDs and display).● Single button operation.● Auto-off/auto-ranging.● Combined prospective short circuit current, PSC and LOOP tester.● Built-in carry case, test leads in separate pouch.● Loop test for L-E and L-N and PSC.● Voltage test L-N and L-E.● Enables analysis of constituent components in L-E and L-N loops giving resistance of earth, neutral wire, live wire and transformer winding.● Display can be customized for special orders.● 60Hz available on request.
-
product
High Performance Polyphase Energy Metering AFE w/ Power Quality Analysis
ADE9000
The ADE9000 is a highly accurate, fully integrated energy-metering device. Interfacing with both current transformer (CT) and Rogowski coil sensors, the ADE9000 enables users to develop a three-phase metrology platform, which achieves high performance for Class 1 through Class 0.2 meters. Power quality features enable advanced meter designs with fast rms measurements and power quality level monitoring for EN50160 compliance. The ADE9000 integrates seven high performances ADC’s, a flexible DSP core. An integrated high-end reference ensures low drift over temperature with a combined drift of less than ±25 ppm/°C max for the whole channel including PGA and ADC.
-
product
Three Phase Power Analyzer
Model PA-600
Power Analyzer Model PA-600 is having advanced measurement capability which gives accurate measurement also at low power factor such as 0.1PF with 0.1% basic accuracy. 16 bit microcontroller and 24bit Analog to digital converter performs accurate measurement & calculation of Voltage, current, power, power factor, crest factor, form factor and frequency with any load and signals of frequencies from 30 Hz to 800 Hz. PA600 is most applicable for no load and full load testing of distribution and power transformer. You can read true RMS value, peak value, mean value and average value of any parameter simultaneously in LCD display.
-
product
Automatic Transformer Observation System
ATOS
Raytech – The World leader in design and manufacturing of high-quality precision measuring instruments and systems, offering flexibility and versatility. Our modular Automatic Transformer Observation System (ATOS) allow you to create a unique and custom solution for any application. ATOS is designed to drastically reduce measuring time and increase test performance, without losing accuracy compared to individual test instruments. With the choice of up to three Multiplexers (primary, secondary, and tertiary), three Winding Resistance Meters, each with three maximum current range options (up to 15A, 50A, or 100A), Turns Ratio, and Integrated power security and safety panel (ISU R), Raytech can create a system with your needs and budget in mind.
-
product
Portable Power Quality Analyzer
PDA 1252
The PDA 1252 is a portable power quality analyzer designed to monitor, isolate and troubleshoot power system disturbances. Using our advanced analysis software, the Communicator EXT application, view real time data presented in a simple and powerful format. Maximize the Communicator EXT application's power with the optional AiReports to generate disturbance solutions and advanced power reports. The unit is ideal for load surveys, program, monitoring transformer banks and indoor/outdoor electrical monitoring. The PDA 1252 Power Quality Analyzer is mounted in its own watertight carrying case and uses watertight connectors to connect voltage and current leads. Based on the Nexus 1252 platform, the PDA 1252 is easy to use and operate.
-
product
Single-Phase Transformer Winding Resistance Meters
RMO-TT Series
RMO-TT series is perfect for measuring winding resistance of inductive objects such as power and distribution transformers or autotransformers. Additionally, every transformer resistance meter from RMO-TT series can analyze:tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.Transformer demagnetization can also be performed with all RMO-TT instruments.The series is consisted of 3 models, with maximal test current from 40 A (RMO40TT) to 100 A (RMO100TT). RMO100TT is the only portable transformer resistance meter in the market with 100 A DC output current.The three independent channels enable testing of three windings in series. Consequently, a user can measure winding resistance in every tap position of an on-load tap changer without discharging between the tests.In addition to winding resistance measurement, a user can perform a detailed on-load tap changer analysis by analyzing recorded graphs (10 kHz sampling rate) and by measuring vibrations on an external tap changer tank.All RMO-TT instruments have a built-in tap changer control unit. Because of this, it is possible to remotely control on-load tap changer (OLTC) directly from the device. Also, a user can program DV-Win software to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.
-
product
DIGITAL TURNS TESTER AND DIGITAL LCRTZ METER
TURNS-LCRTZ
Digital TURNS TESTER with LCR for Counting / Measuring Number of Turns for Toroidal Coils , Current Sensor , Current Transformer , Round Core Coils. Can measure, Turns along with Winding Polarity , DC Resistance , Inductance (L), Capacitance (C), DC Resistance, Rac, Q, D, ESR and Tan.Toroidal Turns Platforms :TTPT100 : 5 T - 1000 T , TTPT1000 : 500T-10000 T The Platform has 2 connections for the coil and 2 for the probe wire. Measurement principle is based on dynamic comparison of the voltage across one turn and the coil. You will be able to get the polarity or winding indication with respect to the one turn reference.Accuracy : + 0.2% + 0.5T for high and medium permeability cores at suitable test frequency. Internal Diameter must be able to pass a wire as thin as 0.2 mm. External Diameter as high as 200 mm.Test Frequency Selectable in Step : 50 Hz, 100 Hz , 500 Hz, 1 KHz, 5 KHz, 10 KHz. Test Voltage adjustable : 100mV to 1V in steps of 50mV.
-
product
1μΩ-4kΩ AC Milliohmmeter Low Resistance Tester
TH2521
Shenzhen Chuangxin Instruments Co., Ltd.
TH2521 AC Milliohmmeter is a high-performance and intelligent tester widely used to test contact resistance, internal resistance and battery voltage. The application of constant current source with 1kHz frequency can greatly eliminate the potential error caused by thermoelectricity on DUT. This meter has the function to automatically detect contact failures on test cable. At the range of 30mΩ, basic R resolution can reach 1μΩ. It is applicable for transformer, inductance coil copper resistance, relay contact resistance, switch, connector contact resistance, wire resistance, PCB line and via reistance dan metal defect detection, etc. In the mean time, signals, such as HIGH, LOW, PASS, can be output through HANDLER interface, thus it is very convenient to be used in automatic production line.
-
product
Microohmmeter
MMR-6500
The MMR-6500 digital meter is designed for measuring low resistances with a stabilised current of up to 100 A. The use of test clamps enables the safe measurement of breakers (high-, medium- and lowvoltage), isolators and other components earthed on both sides. The MMR-6500 series meters are equipped with a unique module in their class that measures inductive components which have a current of up to 10 A, enabling the winding resistance of motors, transformers and other inductive components to be measured. Another useful function is the temperature measurement and the automatic compensation of results with relation to the measured temperature or temperature set by the user. The system is completed with a recorder function. Special measuring algorithms and additional functions allow an appropriate measuring method to be chosen depending on the measured component and measurement conditions, thus, widening the application areas of the meter. The state-of-the-art user interface, various communication interfaces, wireless communication and communication with the computer, printer, 2D code reader are integrals features which enable full, comfortable and intuitive management of not only measurements and their results but also ID data of measured components.